TMP92xy26AXBG Toshiba, TMP92xy26AXBG Datasheet - Page 584

no-image

TMP92xy26AXBG

Manufacturer Part Number
TMP92xy26AXBG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMP92xy26AXBG

Package
FPGA228
Rom Types(m=mask,p=otp, F=flash,e=eeprom)
Romless
Rom Combinations
Romless
Ram Combinations
144/288
Architecture
32-bit CISC
Usb/spi Channels
1/1
Uart/sio Channels
2
I2c/sio Bus Channels
1
(s)dram Controller
1
Adc 10-bit Channel
6
Da Converter
-
Timer 8-bit Channel
8
Timer 16-bit Channel
2
Pwm 8-bit Channels
-
Pwm 16-bit Channels
-
Cs/wait Controller
4
Dual Clock
Y
Number Of I/o Ports
136
Power Supply Voltage(v)
3.0 to 3.6
3.20.4
Touch screen resistor : Rty (Rtx)
The resistance depends on
ON-resistor: Rmy (Rmx)
ON-resistor: Rpy (Rpx)
measuring following the procedure below:
position measurement above can be determined with the ratio between the ON resistance
value of the switch in the TMP92CF26A and the resistance value in the touch screen as
shown in Figure 3.20.5.
will be neither 3.3V nor 0.0V.
during designing. It is also recommended that an average taken from several AD
conversions performed if required be adopted as the final correct value.
X/Y position measuring procedure
During the routine of pen-touch and INT4 interrupt generation, execute a pen position
<X position coordinate measurement>
The above analog voltage which is input to AN3 and AN2 pins during the X and Y
Therefore, even when touching an end area on the touch screen, the analog input voltage
Note that the rate of each resistance varies. Remember to take this into consideration
<Y position coordinate measurement>
the touch screen.
PG3/MY/AN3 pin.
using the AD converter.
PG2/MX/AN2 pin.
AD converter.
SMY (SMX)
Make the SPX and SMX switches ON, and the SPY and SMY switches OFF.
With this setting, an analog-voltage that shows the X position will be input to the
The X-position coordinate can be measured by converting this voltage to digital code
Make the SPY and SMY-switches ON, and the SPX and SMX switches OFF.
With this setting, an analog voltage that shows the Y position will be input to the
The Y position can be measured by converting this voltage to digital code using the
SPY (SPX)
typ.10Ω
typ.10Ω
AVCC=3.3V
Figure 3.20.5 Calculation analog voltage
R1
R2
Touch-point
92CF26A-582
AN2 (AN3)-pin
[Analog input voltage to theAN2 and AN3 pins: Formula to calculate E1]
E1 = ((100+10) / (10+400+100+10) × 3.3
Note1: An X-coordinate position can be calculated in the same way
Note2: Rty = R1+R2.
Ex.) Where AVCC=3.3V, Rpy=Rmy=10Ω, R1=400Ω and R2=100Ω
E1 = ((R2+Rmy) / (Rpy+Rty+Rmy)) × AVCC [V]
though above formula is for Y-coordinate position.
= 0.698V
TMP92CF26A
2009-06-25

Related parts for TMP92xy26AXBG