MCBSTM32EXL Keil, MCBSTM32EXL Datasheet - Page 480

no-image

MCBSTM32EXL

Manufacturer Part Number
MCBSTM32EXL
Description
BOARD EVALUATION FOR STM32F103ZE
Manufacturer
Keil
Datasheets

Specifications of MCBSTM32EXL

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Secure digital input/output interface (SDIO)
Table 128. Card status
480/995
31
30
29
28
27
26
25
24
23
22
21
20
Bits
ADDRESS_
OUT_OF_RANGE
ADDRESS_MISALIGN
BLOCK_LEN_ERROR
ERASE_SEQ_ERROR
ERASE_PARAM
WP_VIOLATION
CARD_IS_LOCKED
LOCK_UNLOCK_
FAILED
COM_CRC_ERROR
ILLEGAL_COMMAND
CARD_ECC_FAILED
CC_ERROR
Identifier
E R X
E X
E X
S R
E X
E R
E R
E X
E R
Type
’0’= no error
’1’= error
’0’= no error
’1’= error
’0’= no error
’1’= error
’0’= no error
’1’= error
’0’= no error
’1’= error
’0’= no error
’1’= error
‘0’ = card
unlocked
‘1’ = card locked
’0’= no error
’1’= error
’0’= no error
’1’= error
’0’= no error
’1’= error
’0’= success
’1’= failure
’0’= no error
’1’= error
Value
Doc ID 13902 Rev 9
The command address argument was out
of the allowed range for this card.
A multiple block or stream read/write
operation is (although started in a valid
address) attempting to read or write
beyond the card capacity.
The commands address argument (in
accordance with the currently set block
length) positions the first data block
misaligned to the card physical blocks.
A multiple block read/write operation
(although started with a valid
address/block-length combination) is
attempting to read or write a data block
which is not aligned with the physical
blocks of the card.
Either the argument of a
SET_BLOCKLEN command exceeds the
maximum value allowed for the card, or
the previously defined block length is
illegal for the current command (e.g. the
host issues a write command, the current
block length is smaller than the maximum
allowed value for the card and it is not
allowed to write partial blocks)
An error in the sequence of erase
commands occurred.
An invalid selection of erase groups for
erase occurred.
Attempt to program a write-protected
block.
When set, signals that the card is locked
by the host
Set when a sequence or password error
has been detected in lock/unlock card
command
The CRC check of the previous command
failed.
Command not legal for the card state
Card internal ECC was applied but failed
to correct the data.
(Undefined by the standard) A card error
occurred, which is not related to the host
command.
Description
condition
C
C
C
C
C
C
A
C
B
B
C
C
RM0008