MCBSTM32EXL Keil, MCBSTM32EXL Datasheet - Page 978

no-image

MCBSTM32EXL

Manufacturer Part Number
MCBSTM32EXL
Description
BOARD EVALUATION FOR STM32F103ZE
Manufacturer
Keil
Datasheets

Specifications of MCBSTM32EXL

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Debug support (DBG)
29.17.6
Note:
29.17.7
29.17.8
Note:
978/995
registers DWT Control Register (bits SYNCTAP[11:10]) and the DWT Current PC Sampler
Cycle Count Register.
The TPUI Frame synchronization packet (0x7F_FF_FF_FF) is emitted:
Synchronous mode
The trace data output size can be configured to 4, 2 or 1 pin: TRACED(3:0)
The output clock is output to the debugger (TRACECK)
Here, TRACECLKIN is driven internally and is connected to HCLK only when TRACE is
used.
In this synchronous mode, it is not required to provide a stable clock frequency.
The TRACE I/Os (including TRACECK) are driven by the rising edge of TRACLKIN (equal to
HCLK). Consequently, the output frequency of TRACECK is equal to HCLK/2.
Asynchronous mode
This is a low cost alternative to output the trace using only 1 pin: this is the asynchronous
output pin TRACESWO. Obviously there is a limited bandwidth.
TRACESWO is multiplexed with JTDO when using the SW-DP pin. This way, this
functionality is available in all STM32F10xxx packages.
This asynchronous mode requires a constant frequency for TRACECLKIN. For the standard
UART (NRZ) capture mechanism, 5% accuracy is needed. The Manchester encoded
version is tolerant up to 10%.
TRACECLKIN connection inside STM32F10xxx
In STM32F10xxx, this TRACECLKIN input is internally connected to HCLK. This means that
when in asynchronous trace mode, the application is restricted to use to time frames where
the CPU frequency is stable.
Important: when using asynchronous trace: it is important to be aware that:
The default clock of the STM32F10xxx MCU is the internal RC oscillator. Its frequency
under reset is different from the one after reset release. This is because the RC calibration is
the default one under system reset and is updated at each system reset release.
Consequently, the Trace Port Analyzer (TPA) should not enable the trace (with the
TRACE_IOEN bit) under system reset, because a Synchronization Frame Packet will be
issued with a different bit time than trace packets which will be transmitted after reset
release.
after each TPIU reset release. This reset is synchronously released with the rising
edge of the TRACECLKIN clock. This means that this packet is transmitted when the
TRACE_IOEN bit in the DBGMCU_CFG register is set. In this case, the word
0x7F_FF_FF_FF is not followed by any formatted packet.
at each DWT trigger (assuming DWT has been previously configured). Two cases
occur:
If the bit SYNENA of the ITM is reset, only the word 0x7F_FF_FF_FF is emitted
without any formatted stream which follows.
If the bit SYNENA of the ITM is set, then the ITM synchronization packets will
follow (0x80_00_00_00_00_00), formatted by the TPUI (trace source ID added).
Doc ID 13902 Rev 9