HD6417760BL200AV Renesas Electronics America, HD6417760BL200AV Datasheet - Page 744

SH4 7760, 17 X17 256BGA, LCDC, U

HD6417760BL200AV

Manufacturer Part Number
HD6417760BL200AV
Description
SH4 7760, 17 X17 256BGA, LCDC, U
Manufacturer
Renesas Electronics America
Series
SuperH® SH7750r
Datasheet

Specifications of HD6417760BL200AV

Core Processor
SH-4
Core Size
32-Bit
Speed
200MHz
Connectivity
Audio Codec, CAN, EBI/EMI, FIFO, I²C, MFI, MMC, SCI, Serial Sound, SIM, SPI, USB
Peripherals
DMA, LCD, POR, WDT
Number Of I /o
69
Program Memory Type
ROMless
Ram Size
48K x 8
Voltage - Supply (vcc/vdd)
1.4 V ~ 1.6 V
Data Converters
A/D 4x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
256-BGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417760BL200AV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6417760BL200AV
Manufacturer:
RENENAS
Quantity:
20 000
• When returning from standby mode to the smart card interface mode:
18.5.6
In order to maintain the clock duty from power-on, the following switching procedure should be
used.
1. The clock output pin is set to an input port as the initial state and is pulled up in the chip.
2. Select the SIM through IPSELR in the PFC.
3. Use the CKE1 bit in SISCR to specify the fixed output.
4. Set the CKE0 bit in SISCR to 1 to start clock output.
18.5.7
An example of pin connections for the smart card interface is shown in figure 18.12.
In communication with the smart card, transmission and reception are performed using a single
data transmission line. The data transmission line should be pulled up by a resistance on the power
supply V
When using the clock generated by the smart card interface with the IC card, the SIM_CLK pin
output is input to the CLK pin of the IC card. If an internal clock of the IC card is used, this
connection is not needed.
Rev. 2.00 Feb. 12, 2010 Page 660 of 1330
REJ09B0554-0200
5. Cancel the standby state.
6. Set the CKE1 bit in SISCR to the value of the output-fixed state at the beginning of
7. Write 1 to the CKE0 bit in SISCR to output a clock signal. Clock signal generation begins
standby (the current SIM_CLK pin state).
at normal duty.
DDQ
Power-On and Clock Output
Pin Connections
SIM_CLK
side.
Figure 18.11 Procedure for Stopping the Clock and Restarting
Normal mode
(1) (2) (3)
(4)
Standby mode
(5) (6) (7)
Normal mode

Related parts for HD6417760BL200AV